Methodology
Formulas, assumptions, warning thresholds and calculation limits.
Formulas
Dew point uses a Magnus approximation. Absolute humidity is derived from saturation vapour pressure. Air replacement uses an ideal-mixing model: the replaced fraction is 1−e−n·t.
Warning thresholds
Surface thresholds of 80%, 90% and 100% RH are screening indicators. They do not predict the growth of a specific mould species. EPA identifies moisture control as the key to mould control and advises keeping indoor RH below 60%, ideally 30–50% where possible.
Sources
- US EPA — Why and Where Mold Grows
- US EPA — Mold, Moisture and Your Home
- WHO — Dampness and Mould
- ASHRAE Standards and Guidelines
Limitations
The service does not check legal compliance or design a ventilation system. Real airflow requires measurement, while reverse draught, combustion fumes, leaks and major water damage need a professional.